OLE UV-C Ceiling Mounted

UVC Disinfection
Technical Information
Download
Enquiry
Electrical
Input Voltage : 220 to 240V
Input Frequency : 50 to 60Hz
Main Voltage Performance (AC) : 202 to 254V
System Power Consumption : 40W and 80W
Total Lamp Power : 36W and 72W
UV-C Radiation at 100hr : 22W (5.5W per side)

Lamp & Electronics

Light Source : Philips UV-C Lamp 2x PL-L 18W and 4x PL-L 18W
Gear : High Frequency Electronic Ballast
Useful Life : 9000h

Mechanical

Housing Material : Steel
Reflector Material : Aluminium
Mounting : Ceiling Mounted
Dimension : 555mm(L), 91mm(H), 555mm(D)
Installation : 100mm below recessed plate in false ceiling, with ceiling height minimum 2.5m from floor level
Ensuring Safe Exposure : Minimum distance from floor to the underside of the fitting should be 2.3m
Minimum distance from ceiling to the upperside of the fitting should be 100mm
Ensuring recessed plate in false ceiling stay in horizontal level
Minimum distance from wall to the fitting should be 3.6m
Weight : 5.5kg